{"id":380,"date":"2025-10-28T12:00:00","date_gmt":"2025-10-28T08:30:00","guid":{"rendered":"https:\/\/saeedshariati.net\/en\/?p=380"},"modified":"2026-10-10T01:21:40","modified_gmt":"2026-10-09T21:51:40","slug":"knx-vs-conventional-installation","status":"publish","type":"post","link":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/","title":{"rendered":"KNX vs Conventional Installation: What&#8217;s the Difference?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">If you&#8217;re used to traditional electrical installations, KNX can feel like a different world at first. The good news: the physical layer isn&#8217;t as unfamiliar as it seems. In most KNX installations, a simple <strong>control cable<\/strong> runs parallel to the usual 230 V power cable \u2014 and from that one addition, a whole set of advantages emerges.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article explains how KNX differs from conventional installation technology, what the control cable actually does, and why KNX works just as well in a small flat as in a large hotel.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Twisted Pair: A Cable That Changes Everything<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In the most widely used KNX medium \u2014 <strong>Twisted Pair (TP)<\/strong> \u2014 a <strong>control cable<\/strong> is laid parallel to the 230 V power cable. That&#8217;s the core physical difference from conventional installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This single addition brings three major advantages over traditional wiring:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Considerably less cabling<\/strong> \u2014 especially when bus devices are arranged in a decentralized way<\/li>\n\n\n\n<li><strong>More system functions<\/strong> \u2014 the same installation can support a wider range of features<\/li>\n\n\n\n<li><strong>Better transparency<\/strong> \u2014 the installation becomes easier to understand, document, and maintain<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In other words, KNX doesn&#8217;t just replace the wiring \u2014 it reorganizes how the installation itself is conceived.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you&#8217;re new to the KNX ecosystem, you may want to start with our <a href=\"\/posts\/knx-smart-building-standard\/\" target=\"_blank\" rel=\"noreferrer noopener\">complete overview of the KNX smart building standard<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does the Control Cable Do?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The control cable isn&#8217;t just an extra wire \u2014 it plays two essential roles:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>It connects loads (actuators) and switches (sensors)<\/strong> \u2014 the two fundamental device categories in any KNX installation<\/li>\n\n\n\n<li><strong>It supplies power to the bus devices<\/strong> in most cases<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This dual function is one of the reasons KNX installations remain compact and efficient. There&#8217;s no need for a separate power line running to every device \u2014 the bus itself carries both the signal and, in most cases, the power.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Decentralized Intelligence: No Central Controller Needed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Perhaps the most important conceptual difference from conventional systems is this:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Every KNX bus device has its own intelligence.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This means a <strong>central control unit<\/strong> \u2014 such as a PC \u2014 is <strong>not necessary<\/strong>. There&#8217;s no single point of failure, no master device that everything depends on. Each device knows what to do, and the system as a whole coordinates through the bus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This decentralized architecture is what makes KNX so flexible. It can be used:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In <strong>small installations<\/strong> \u2014 such as flats and single-family homes<\/li>\n\n\n\n<li>In <strong>large projects<\/strong> \u2014 such as hotels, administration buildings, and commercial towers<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The same underlying principle scales from a two-room apartment to a multi-floor facility without changing the core design philosophy.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why This Matters in Practice<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For installers and system integrators, the differences translate into real, day-to-day benefits:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Less wiring<\/strong> means faster installation and lower material costs<\/li>\n\n\n\n<li><strong>More functions<\/strong> on the same cabling means better value for the end user<\/li>\n\n\n\n<li><strong>Decentralized intelligence<\/strong> means no single point of failure and easier troubleshooting<\/li>\n\n\n\n<li><strong>Scalability<\/strong> means the same skill set applies from small projects to large ones<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In short: KNX keeps the installation simple while expanding what it can do.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udccc Key Takeaways<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>In KNX <strong>Twisted Pair (TP)<\/strong> installations, a <strong>control cable<\/strong> runs parallel to the 230 V power cable.<\/li>\n\n\n\n<li>This reduces cabling, increases possible system functions, and improves installation transparency.<\/li>\n\n\n\n<li>The control cable connects <strong>actuators and sensors<\/strong>, and in most cases <strong>supplies power<\/strong> to bus devices.<\/li>\n\n\n\n<li>Since every KNX device has its own intelligence, <strong>no central control unit is required<\/strong>.<\/li>\n\n\n\n<li>KNX scales from <strong>small flats<\/strong> to <strong>large buildings<\/strong> such as hotels and administration buildings.<\/li>\n\n\n\n<li>New to KNX? Start with our <a href=\"\/posts\/knx-smart-building-standard\/\" target=\"_blank\" rel=\"noreferrer noopener\">complete overview of the KNX smart building standard<\/a>.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>If you&#8217;re used to traditional electrical installations, KNX can feel like a different world at first. The good [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":383,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[31],"tags":[25,48,20,49,47],"class_list":["post-380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knx-training","tag-building-automation","tag-conventional-installation","tag-knx","tag-knx-bus","tag-twisted-pair"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KNX vs Conventional Installation: What&#039;s the Difference? - Saeed Shariati<\/title>\n<meta name=\"description\" content=\"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KNX vs Conventional Installation: What&#039;s the Difference? - Saeed Shariati\" \/>\n<meta property=\"og:description\" content=\"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/\" \/>\n<meta property=\"og:site_name\" content=\"Saeed Shariati\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-28T08:30:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-09T21:51:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1344\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Saeed Shariati\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Saeed Shariati\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/\"},\"author\":{\"name\":\"Saeed Shariati\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/#\\\/schema\\\/person\\\/95b146ad1955fd7774314cf3cfa15d2e\"},\"headline\":\"KNX vs Conventional Installation: What&#8217;s the Difference?\",\"datePublished\":\"2025-10-28T08:30:00+00:00\",\"dateModified\":\"2026-10-09T21:51:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/\"},\"wordCount\":592,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/KNX-vs-Conventional-Installation.jpg\",\"keywords\":[\"Building Automation\",\"conventional installation\",\"KNX\",\"KNX bus\",\"twisted pair\"],\"articleSection\":[\"KNX Training\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/\",\"url\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/\",\"name\":\"KNX vs Conventional Installation: What's the Difference? - Saeed Shariati\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/KNX-vs-Conventional-Installation.jpg\",\"datePublished\":\"2025-10-28T08:30:00+00:00\",\"dateModified\":\"2026-10-09T21:51:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/#\\\/schema\\\/person\\\/95b146ad1955fd7774314cf3cfa15d2e\"},\"description\":\"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/KNX-vs-Conventional-Installation.jpg\",\"contentUrl\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/KNX-vs-Conventional-Installation.jpg\",\"width\":1344,\"height\":768,\"caption\":\"KNX-vs-Conventional-Installation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/knx-vs-conventional-installation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KNX vs Conventional Installation: What&#8217;s the Difference?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/\",\"name\":\"Saeed Shariati\",\"description\":\"My focus is on the core technical concepts behind smart technology and energy, conveyed through practical, project-based applications rather than abstract theory. A professional venture is taking shape.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/#\\\/schema\\\/person\\\/95b146ad1955fd7774314cf3cfa15d2e\",\"name\":\"Saeed Shariati\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa\",\"caption\":\"Saeed Shariati\"},\"sameAs\":[\"https:\\\/\\\/saeedshariati.net\\\/en\"],\"url\":\"https:\\\/\\\/saeedshariati.net\\\/en\\\/posts\\\/author\\\/saeedshariati-en\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KNX vs Conventional Installation: What's the Difference? - Saeed Shariati","description":"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/","og_locale":"en_US","og_type":"article","og_title":"KNX vs Conventional Installation: What's the Difference? - Saeed Shariati","og_description":"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.","og_url":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/","og_site_name":"Saeed Shariati","article_published_time":"2025-10-28T08:30:00+00:00","article_modified_time":"2026-10-09T21:51:40+00:00","og_image":[{"width":1344,"height":768,"url":"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg","type":"image\/jpeg"}],"author":"Saeed Shariati","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Saeed Shariati","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#article","isPartOf":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/"},"author":{"name":"Saeed Shariati","@id":"https:\/\/saeedshariati.net\/en\/#\/schema\/person\/95b146ad1955fd7774314cf3cfa15d2e"},"headline":"KNX vs Conventional Installation: What&#8217;s the Difference?","datePublished":"2025-10-28T08:30:00+00:00","dateModified":"2026-10-09T21:51:40+00:00","mainEntityOfPage":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/"},"wordCount":592,"commentCount":0,"image":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#primaryimage"},"thumbnailUrl":"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg","keywords":["Building Automation","conventional installation","KNX","KNX bus","twisted pair"],"articleSection":["KNX Training"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/","url":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/","name":"KNX vs Conventional Installation: What's the Difference? - Saeed Shariati","isPartOf":{"@id":"https:\/\/saeedshariati.net\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#primaryimage"},"image":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#primaryimage"},"thumbnailUrl":"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg","datePublished":"2025-10-28T08:30:00+00:00","dateModified":"2026-10-09T21:51:40+00:00","author":{"@id":"https:\/\/saeedshariati.net\/en\/#\/schema\/person\/95b146ad1955fd7774314cf3cfa15d2e"},"description":"How does KNX differ from conventional electrical installation? Discover the role of the Twisted Pair control cable, the advantages of decentralized intelligence, and why KNX scales from flats to large buildings.","breadcrumb":{"@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#primaryimage","url":"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg","contentUrl":"https:\/\/saeedshariati.net\/en\/wp-content\/uploads\/2025\/10\/KNX-vs-Conventional-Installation.jpg","width":1344,"height":768,"caption":"KNX-vs-Conventional-Installation"},{"@type":"BreadcrumbList","@id":"https:\/\/saeedshariati.net\/en\/posts\/knx-vs-conventional-installation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/saeedshariati.net\/en\/"},{"@type":"ListItem","position":2,"name":"KNX vs Conventional Installation: What&#8217;s the Difference?"}]},{"@type":"WebSite","@id":"https:\/\/saeedshariati.net\/en\/#website","url":"https:\/\/saeedshariati.net\/en\/","name":"Saeed Shariati","description":"My focus is on the core technical concepts behind smart technology and energy, conveyed through practical, project-based applications rather than abstract theory. A professional venture is taking shape.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/saeedshariati.net\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/saeedshariati.net\/en\/#\/schema\/person\/95b146ad1955fd7774314cf3cfa15d2e","name":"Saeed Shariati","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa","url":"https:\/\/secure.gravatar.com\/avatar\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/83a5cea713aea3a37fdb840d09266757fafb794b2a3d617c05d313ca6a9480fe?s=96&d=initials&r=g&initials=sa","caption":"Saeed Shariati"},"sameAs":["https:\/\/saeedshariati.net\/en"],"url":"https:\/\/saeedshariati.net\/en\/posts\/author\/saeedshariati-en\/"}]}},"_links":{"self":[{"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/posts\/380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/comments?post=380"}],"version-history":[{"count":1,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/posts\/380\/revisions"}],"predecessor-version":[{"id":382,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/posts\/380\/revisions\/382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/media\/383"}],"wp:attachment":[{"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/media?parent=380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/categories?post=380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/saeedshariati.net\/en\/wp-json\/wp\/v2\/tags?post=380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}